Sales (Toll Free) – 1800 425 200 000

Services (Toll Free) – 1800 425 11 45

Back-up Power Systems

Sinicon, established in 1994, has been contributing its share of knowledge in improving the living quality of people by way of providing them with superior quality products made on latest technology platform.

Home > Back-up Power Systems (EPS Eco)

EPS Economical: Features

  • LCD display /LED display
  • Table top
  • Plastic Cabinet
  • Sine wave
  • DSP based technology
  • Automatic Changeover.
  • Protections against: Overload, short circuit, battery deep discharge, battery over charge, mains over voltage. In all these error conditions will be shown in the LCD display.
  • Delayed inverter cutoff for conditions like battery low, overload, short circuit etc. The system will automatically restart from cutoff after a few second buzzer beeps. The system will go to permanent cutoff if the error condition exists even after 4 restart.
  • Suitable for concealed or external wiring.
  • Available in 500VA,800VA,1000VA,1500VA.
  • Pollution free and easily serviceable.

LCD will display –

  • Battery voltage
  • Inverter output voltage
  • Percentage of load
  • Mains voltage
  • Changer on/off
  • Inverter standby on/off
  • UPS mode / inverter mode
  • Phase input output reverse : whether mains is connected to inverter output
  • Short circuit
  • Overload trip
  • Short circuit trip

LED Will Display

  • Mains
  • Inverter/UPS
  • Charging
  • Low Battery
  • Overload
Description EPS 500 EPS 800 EPS 1000 EPS 1500
EPS500
Input Power Supply 240VAC 240VAC 240VAC 240VAC
EPS Output 220VAC 220VAC 220VAC 220VAC
EPS Capacity 400VA 640VA 800VA 1200VA
Maximum Load 400W 640W 800W 1200W
EPS Frequency 50Hz 50Hz 50Hz 50Hz
Battery Voltage 12VDC 12VDC 24VDC 24VDC
Type of Load All Types All Types All Types All Types
Offline UPS Yes Yes Yes Yes
Battery Trolley Optional Optional Optional Optional
Dimension without Battery Trolley (in mm)
Height 125 125 150 150
Width 350 350 350 350
Depth 290 290 290 290


Indicative Load Details for EPS Sizing

Description of Load Load(W) Description of Load Load(W)
PC with colour monitor 250 Ceiling Fan 70
Printer 80 Pedestal Fan 50
Fluorescent Light 48 Centrifuge 80
Television 80    


Indicative Battery Back-up Time Chart

Battery AH 500VA Backup time(Approx)
12V 65AH 1 Hour
12V 100AH 1 Hour 45 Minutes
12V 120AH 2 Hour
12V 135AH 2 Hour 30 Minutes
12V 180AH 3 Hour